ULTRAHEAT S/AIR

Light, completely air-cooled units.
No water cooling system required.
Perfect for low temperature applications T<500°F/ 260°C.
SMT models featuring advanced 5” LCD touch screen with multiple programs, temperature control and diagnostics features.
Reliable, modular system, easy to maintain and service.
Flexible, wide range load impedance matching by utilizing multiple transformer ratios and configurable tank capacitance.
Automatic frequency scanning and easy tuning to variety of loads and coils.
Durable design, loaded with safety and diagnostics features.

UltraHeat S AIR – 5kW Induction Heating Systems

STANDARD FEATURES

  • Output regulation – Voltage, Power, Current
  • Limits setting – Current, DC Volts, Output Volts, Power, Frequency
  • Compact air -cooled power supply design with automatic fan control
  • Operator controls – Selectable: Automatic, Remote or Local
  • Multiple user programs and programmable parameters
  • Capable of delivering full power in the specified frequency range (see Specifications tables)
  • Variable ratio output isolation transformer for load matching of a wide range of loads and coils
  • Power control from 1% to 100% in 1% increments

ADVANCED OPTIONS

  • Advanced 5” Color LCD touch panel
  • Digital I/O Interface board – Remote Start/Stop
  • External power control input: 0-10V or 4-20mA
  • Temperature monitoring & control with K type thermocouple
  • Temperature regulator for standard IR sensor input
  • Serial Interface: RS-232 or RS-485
  • Data logging and remote diagnostics
Power Supply Model

● Standard ○ Optional

SM-2A
0UPT-030-230
SM-5A
0UPT-030-330
SMT-2A
0UPT-030-230
SMT-5A
0UPT-030-330
Output kW 2.0kW 4.0kW 2.0kW 4.0kW
Frequency kHz 20-100 20-100 20-100 20-100
AC Line Volts (50/60Hz) 110/230±10% 110/230±10% 110/230±10% 110/230±10%
Line Phases 1 1 1 1
Compact air cooled power supply
Auto tuning to variety of loads and coils
Control panel Standard Standard 5” LCD Touch 5” LCD Touch
User programs 5 5 20 20
Digital I/O & Analog Power Control
Temperature control with
K Thermocouple Input
Cycle Energy Monitor
Serial Interface: RS-232 or RS-485
Data logging
Weight Lb (kg) 11 (5) 28 (12.5) 11 (5) 28 (12.5)
Dimensions
Inch (cm) WxDxH
9.8” x 8.5” x 9.3”
(25 x 21.5 x 23.5)
14.4” x 10.6” x 12.8”
(36.5 x 27 x 32.6)
9.8” x 8.5” x 9.3”
(25 x 21.5 x 23.5)
14.4” x 10.6” x 12.8”
(36.5 x 27 x 32.6)
Compatible Heat Stations HS-4AN HS-4AN HS-4AN HS-4AN
Heat Station Model
HS-4AN (1ACC-030-200)
Air-cooled
Cable Length between
Power Supply and Heat Station:
Std / Max
Ft (cm)
6 (183)/ 30 (914)
Dimensions
Inch (cm) WxDxH
7.3” x 14.2” x 7.1”
(18.5 x 36.1 x 18)
Weight Lb (kg) 13 (6)
Cooling requirements
water system quoted upon request
n/a
Min. Cooling Water,
GpM (LpM)
n/a
Inlet Water T° (max),F (°C) n/a
Power supply:

  • RS-232 or RS-485 interface for remote computer monitoring, control and diagnostics
  • External power control input: 0-10 V or 4-20 mA
  • External Controls – Start/Stop operation, External Fault

Heat Station:

  • External Controls – Start/Stop/Foot Switch
Equipment Description Part Number
Custom Coil Custom Coil
designed and manufactured for customer’s application.
WCA-1000-02 Water Cooling System
3.0 kW, 230 VAC,1-ph
1ACC-900-100-00
External E-stop box with 6 ft leads for induction heating machine. Ultraflex Power Technologies.

RCP-03

External E-stop box with 6 ft leads 1ACC-725-530-00
Foot Switch Assembly for induction heating machine. Ultraflex Power Technologies.

FS-01

Foot Switch Assembly 1ACC-777-500-00
ACC-01 Output Coil Adapter 1ACC-754-560-00
ACC-02 Output Adapter Blocks
with 1-4 NPTF
1ACC-030-001-XX
IR-XX Temperature Control and Monitoring Systems
CAB-WCL-600-XX Flexible water cooled leads, from 3 – 15 ft. 1ACC-530-700-XX

PICTURES

APPLICATIONS

Sealing, fatigue testing, Shrink FittingCuringBonding.