UltraHeat M Series
UltraHeat M Series – Obsolete product!
Please check our new model SOLO Series
Advanced, cost-effective power supplies utilizing the latest switching power supply technology.
Induction Heating using adaptive digital phase control providing very efficient operation in a wide frequency range.
Reliable, modular system, easy to maintain and service.
Flexible, wide range load impedance matching by utilizing multiple transformer ratios and configurable tank capacitance.
Configured to operate with external Heat Stations allowing output connections to be available from all sides.
Durable design, loaded with safety and diagnostics features.
Serial Communication link to a PC based software (optional).
FEATURES
- Output regulation – Voltage, Power, Current
- Limits Setting – Current, DC Volts, Output Volts, Power, Frequency
- Operator controls – Selectable: Automatic, Remote or Local
- Capable of delivering full power in the 10-150kHz frequency range
- Variable ratio output isolation transformer for load matching of a wide range of loads and coils
- RS485 interface for remote computer monitoring, control and diagnostics
- Power control from 10 to 100% in 1% increments
- 5 programs with 9 programmable parameters
- 0-10V or 4-20mA external control and remote Start/Stop operation
Power Supply Model | M25/50 0UFX-777-400 | M25/150 0UFX-777-300 | M35/50 0UFX-777-200 | M35/150 0UFX-777-100 |
Output kW | 25 | 25 | 35 | 35 |
Frequency kHz | 10-50 | 50-150 | 10-50 | 50-150 |
AC Line Volts (50/60Hz) | 380/480 ±10% | 380/480 ±10% | 380/480 ±10% | 380/480 ±10% |
Line Phases | 3 | 3 | 3 | 3 |
Weight lbs (kg) | 335 (150) | 335 (150) | 335 (150) | 335 (150) |
Dimensions Inch (cm) WxDxH | 23.6 x 18.9 x 51.2 (60 x 48 x 130) | 23.6 x 18.9 x 51.2 (60 x 48 x 130) | 23.6 x 18.9 x 51.2 (60 x 48 x 130) | 23.6 x 18.9 x 51.2 (60 x 48 x 130) |
Compatible Heat Stations | HS-35, HS-35LF | HS-35, HS-35LF | HS-35, HS-35LF | HS-35, HS-35LF |
Heat Station Model | HS-35MF 1ACC-777-200 | HS-35LF 1ACC-777-250 |
Cable Length between Power Supply and Heat Station: Std / Max Ft (cm) | 10 / 20 (305 / 610) | 10 / 20 (305 / 610) |
Weight lbs (kg) | 106.8 (48) | 129.1 (58) |
Dimensions Inch (cm) WxDxH | 25.7 x 15.9 x 12.9 (65.4 x 40.5 x 32.7) | 27.6 x 15.9 x 12.9 (70 x 40.5 x 32.7) |
Cooling requirements water system quoted upon request | water (external) | water (external) |
Min. Cooling Water GpM (LpM) | 2 GPM (8 lpm) | 2 GPM (8 lpm) |
Inlet Water T° min/max °F (°C) | 60/95°F (15/35°C) | 60/95°F (15/35°C) |
Min water pressure PSI (Bar) | 45 (3) | 45 (3) |
- Improved energy efficiency
- Higher degree of controllability
- Increased repeatability
- Low maintenance requirements
- Increased productivity
Equipment | Description | Part Number |
Custom Coil | Custom Coil designed and manufactured for customer’s application. | |
Water Cooling System | Water Cooling System specified per customer’s requirements | |
RCP-01 | Remote Control Panel with 10 ft cable | 1ACC-777-520-00 |
RCP-03 | External E-stop box with 16 ft leads | 1ACC-725-530-00 |
WA1 | 1″ Water Adaptor Fittings | 9VLO-000-214-00 |
WA2 | NPT Female X BSPT Male Adapter 3/4″ | 9VLO-000-213-00 |
WA3 | Female X BSPT Male adapter | 9VLO-000-212-00 |
WA4 | NPT Female X BSPT Male Adapter 1/4 pipe size | 9VLO-000-211-00 |
HSB-100 | Heat Station Switch Unit (100A) | 1ACC-777-810-00 |
CAB-WCL-900-XX | Flexible water cooled leads, from 3 – 15 ft | 1ACC-530-710-XX |
IR systems | Temperature monitoring and control systems |