1. Q: Can you regulate the emissivity?

A: Yes, we have this feature built in.

2. Q: Do you have thermo reader?

A: Yes, we have an accurate temperature reader with advanced thermo regulator.

3. Q: Is the Vacuum-Argon washing cycle available in SuperCast?

A: Yes, SuperCast has the Vacuum-Argon washing cycle feature.

4. Q: Do we need a crucible tong to take the crucible safe out of the machine?

A: Yes, crucible tongs are crucial part of the safety operation of the machine.

5. Q: Do you have a guide for casting Titanium with SuperCast?

A: Yes, we have a guide to help you with casting Titanium. You can find it here

6. Q: What Oil do you use in your Vacuum Pump?

A: A: The oil we use is DVP BV 32 (Viscosity at 40 оС – 32 (cSt); Max. Operating temperature – 120 оС; Flash point – 195 оС;)
You can also use one of these substitutes:
1/ ESSO – INVAROL EP46;
2/ SHELL – TELLUS T32;
3/ Q8 – HAENDEL 32;